8U Sideways Wall-Mount Rack for Servers

$451.99

Mount your server and networking equipment to the wall, with side mounting for hassle-free access to rear cabling

SKU: RK819SIDEM Category:

Specifications & Compliance

UPC
065030846806
Brand
StarTech.com
Included in Package
1 - 8U Rack, 36 - M5 Screws, 36 - M5 Cage Nuts
Shipping (Package) Weight
46.3 lb [21 kg]
Weight of Product
39.8 lb [18.0 kg]
Product Length
22.2 in [56.5 cm]
Product Width
21.2 in [53.8 cm]
Product Height
19.0 in [48.3 cm]
Package Depth
22.7 in [57.6 cm]
Package Width
23.5 in [59.6 cm]
Package Height
20.4 in [51.7 cm]
Color
Black
Warranty
Lifetime
Package Quantity
1
Material
Steel
Industry Standards
EIA/ECA-310-E
U Height
8U
Wallmountable
Yes
Frame Type
Open Frame
Maximum Mounting Depth
20.8 in [52.9 cm]
Construction Material
Steel
Rack Type
4-Post
Flat Pack (Assembly Required)
No
Mounting Hole Types
Square (For Cage Nut)
Mounting Rail Profile
L-Shape
Special Features
Ships Fully Assembled, Wall-Mountable
Weight Capacity (No Casters)
350.6 lb [159 kg]

Questions & Answers

How do I assemble a StarTech.com server rack?
It depends on the StarTech.com server rack model. Follow the assembly order and fastening pattern in the product manual. In general, verify all parts and tools, set the adjustable beams to the same rack depth, assemble the vertical rails and brackets, confirm the orientation and fastening pattern, tighten all screws, and then install the casters and server rack accessories. Explanation : Before assembling a StarTech.com server rack, make sure there is enough space to build the rack. If the assembled rack will be moved, confirm that it will fit through the required doors and hallways. Before assembly: Remove all parts from the box and confirm that they match the parts listed in the product manual. Confirm that you have all required tools. Refer to the product manual for the correct assembly order and fastening pattern. During assembly: Assemble the adjustable beams first. The adjustable beams control the rack depth and are marked with index numbers. Select the appropriate index number for your equipment using the measurement chart in the product manual, and use the same index number on every adjustable beam. Initially tighten screws only finger-tight. This makes adjustments easier if components need to be repositioned. Use the adjustable beams to align one set of left and right vertical rails with the top and base brackets. Building the rack on its side may make assembly easier. Make sure the index numbers on the adjustable beams and vertical rails face the correct direction. Follow the fastening pattern specified in the product manual. The fastening pattern is essential to rack stability and must be consistent at each corner. For the rack described here, the screw passes through the top or base bracket, then through the vertical rail, and then into the adjustable beam. Attach the remaining two vertical rails and adjustable beams. Before fully tightening the screws, verify that: All adjustable beams are set to the correct and matching index numbers. The beams and rails face the correct direction. The fastening pattern is correct at every corner. All cable guides face the same direction. After confirming the assembly, tighten all screws without stripping them. Install the casters and other server rack accessories so they face the same direction. Inverting the server rack may make caster installation easier. If you experience problems assembling a StarTech.com server rack, contact StarTech.com Technical Support for assistance.

How do I use cage nuts to mount equipment in a server rack?
This video explains what cage nuts are, how to install and remove cage nuts in a compatible server rack, and how to determine whether a StarTech.com product includes cage nuts. Explanation : Cage nuts are used to mount IT equipment in server racks, such as the StarTech.com 4POSTRACK25U. Server racks that support cage nuts can be identified by the square mounting holes in the rack rails. Cage nuts help protect equipment from stripped threads and provide a convenient way to mount server rack equipment. A cage nut contains a standard nut inside a spring cage with two wings. The wings can be pinched together so the cage nut can be inserted into a square mounting hole. When the wings are released, they hold the cage nut securely in place. Cage nuts are available in multiple sizes. M5 and M6 cage nuts are commonly used in IT environments. M6 cage nuts are heavier and more robust than M5 cage nuts. The video demonstrates how to mount a cage nut on a rail in the StarTech.com 4POSTRACK25U. Although a slot screwdriver may be recommended for installing cage nuts in some situations, a cage nut mounting tool can make installation easier. To install a cage nut, use the cage nut mounting tool to engage one wing of the cage nut. Maintain pressure on the cage nut with your finger, then engage the other wing. Once both wings are secured in the square mounting hole, the cage nut is ready for the mounting screw. To remove a cage nut, use the cage nut mounting tool to release the cage nut wing on one side, then release the wing on the other side. To determine whether a StarTech.com product includes cage nuts, find the product on the StarTech.com website and check Technical Specifications under What’s in the Box . StarTech.com also sells M5 and M6 cage nuts and screws. These products are available under Server Rack Accessories > Mounting Screws and Cage Nuts .

How do I safely install equipment in a server rack?
Install the heaviest server rack equipment at the bottom of the rack first to create a stable base and reduce the risk of the rack becoming top-heavy. Use cage nuts and mounting screws to secure compatible rack equipment, and verify that the equipment is securely installed after tightening the screws. Explanation : When installing server rack equipment, start with the heaviest equipment at the bottom of the rack. This approach provides a stable base and helps prevent the rack from becoming top-heavy and falling over, especially when installing multiple devices in a tall rack. For equipment that is long, heavy, unbalanced, or difficult to handle, have another person assist with the installation to help prevent injury or equipment damage. For equipment such as a patch panel that mounts using cage nuts, install the cage nuts in the rack first. Position the equipment, insert the mounting screws into the cage nuts, and tighten the screws without stripping or damaging them. Use extra care with electric tools because they can apply more torque. After installation, confirm that the rack equipment is securely mounted. If you have questions about installing equipment in a server rack, contact the technical support team for assistance.

How do I check if a StarTech.com shelf is compatible with my server rack?
A StarTech.com shelf will fit a server rack if the rack supports 19-inch standard mounting and the shelf depth is within the rack’s supported mounting depth range. Explanation: StarTech.com server racks use the industry-standard 19-inch width, so most shelves designed for 19-inch racks are physically compatible in width. However, compatibility depends primarily on mounting depth and mounting type. Mounting depth compatibility: For shelves that mount on all four posts (4-post racks or cabinet racks), the shelf depth must fall within the rack’s minimum and maximum mounting depth. Both values are listed in the Technical Specifications of the rack and shelf product pages. If the shelf depth exceeds or does not reach the supported range, the shelf cannot be installed. Front-mount shelves: For shelves that mount only on the front posts (2-post mounting), mounting depth is not a constraint. However, there must be sufficient rear clearance in the rack to accommodate the full depth of the shelf and any installed equipment. Accessory validation: If a shelf is listed under the “Accessories” tab on a specific StarTech.com server rack product page, it has been verified as compatible with that rack model.

What is a server rack, and how do I determine whether it will work for my equipment?
A server rack is a standardized framework used to mount and organize IT, networking, and AV equipment. To determine whether a server rack will work in your environment, you must verify the rack unit (U) capacity, mounting depth, weight capacity, rack type, and compatibility with your equipment and accessories. Explanation: Server racks help organize and secure equipment such as servers, network switches, patch panels, UPS systems, and AV hardware. Selecting the correct server rack requires understanding several key specifications. Understanding Rack Units (U) Rack space is measured in rack units (U). 1U = 1.75 inches (44.45 mm) of vertical rack space A 12U rack provides 12 rack units of usable mounting height Equipment can occupy more than 1U of rack space Before purchasing a rack, add together the rack unit requirements of all equipment and accessories to ensure sufficient capacity. 2-Post vs. 4-Post Server Racks Server racks are commonly available in two configurations, 2-post and 4-post. A 2-post rack is often used for: Network switches Patch panels Telecom equipment A 4-post rack is typically recommended for: Servers UPS systems Storage equipment Heavier rack-mounted devices Open vs. Enclosed Server Racks Many 4-post racks are available in either open-frame or enclosed cabinet designs. Open-frame racks Provide easy equipment access Simplify cable routing Promote airflow Are typically used in dedicated IT rooms Enclosed server racks Include lockable doors and side panels Provide physical security Help reduce equipment noise Restrict unauthorized access Enclosed racks may use: Mesh doors for improved airflow Glass doors for visibility and security Understanding Mounting Depth Many 4-post server racks feature adjustable mounting rails. Two important specifications are Minimum Mounting Depth and Maximum Mounting Depth. Minimum Mounting Depth refers to the shortest distance between front and rear mounting rails. Maximum Mounting Depth refers to the longest equipment mounting depth supported by the rack. The maximum mounting depth must be greater than or equal to the depth of the equipment being installed. When equipment is installed close to the rack's maximum depth, there may be limited space available for: Power cables Network cabling Cable management accessories Always verify the depth requirements of: Servers UPS systems Network equipment Rack accessories Compatibility Considerations Before selecting a server rack, verify: Available rack units (U) Mounting depth requirements Rack weight capacity Equipment dimensions Ventilation requirements Cable management needs Some rack-mounted accessories also specify minimum and maximum mounting depths. Review the technical specifications for both the rack and the accessory to ensure compatibility. Mobility and Installation Options Server racks can be installed in different ways depending on the deployment environment. Common options include: Freestanding installation Floor-bolted installation Mobile installation using casters Some server racks include casters, while others support optional caster kits. If mobility is required, verify that compatible casters are available for the specific rack model. Additional Planning Considerations When designing a rack installation: Equipment can often be mounted from both the front and rear of a 4-post rack, provided the combined equipment depth does not exceed the rack's maximum mounting depth. Leave sufficient room for cable management, airflow, and future expansion. Verify that the rack's weight rating supports the total installed equipment load. Consider physical security, accessibility, and cooling requirements when choosing between open-frame and enclosed designs.

What server rack accessories are available, and how do I choose the right ones?
Server rack accessories include shelves, rack rails, DIN rails, casters or leveling feet, cable management solutions, blanking panels, and power distribution units (PDUs). The correct accessories depend on equipment size, weight, mounting requirements, airflow needs, and power distribution requirements. Explanation: Server rack accessories are used to support equipment mounting, improve airflow, organize cabling, and distribute power. Each accessory type serves a specific function and must be selected based on technical compatibility and deployment requirements. Shelves: Server rack shelves are defined by U height (1U = 1.75 inches) and mounting depth. Types include fixed, adjustable, sliding, drawer, cantilever, and heavy-duty shelves. Fixed shelves require equipment to match the shelf depth. Adjustable and sliding shelves support a range of mounting depths. Weight capacity and venting must be verified to ensure proper support and airflow. Rack rails and DIN rails: Rack rails allow mounting of equipment that is not natively rack-mountable and are often depth-adjustable. DIN rails follow an industry-standard mounting format and can be installed in standard 19-inch racks using compatible kits. U size and depth compatibility must be confirmed. Casters and leveling feet: Casters provide mobility, while leveling feet provide stability for stationary installations. Availability and compatibility depend on the specific server rack model and included hardware. Cable management: Cable management accessories include D-ring hooks, cable ducts (conduits), and cable management panels. These components organize and route cables, prevent tangling or strain, and improve airflow. Panels combine multiple management features into a single unit. Blanking panels: Blanking panels (filler panels) cover unused rack units to improve airflow, maintain proper thermal conditions, and restrict physical access to internal components. They are available in vented or solid designs. Power Distribution Units (PDUs): PDUs provide additional power outlets within the rack and are available in multiple U sizes (for example, 1U). Advanced PDUs may support remote power switching over a network. The number of outlets, electrical capacity, and physical size must match the rack and connected equipment. To select the correct server rack accessories, verify U size, depth, weight capacity, mounting compatibility, airflow requirements, and power specifications in the product’s technical documentation.